Pentair 476000 Combustion Blower Replacement Kit for ETi 400 Heaters
The Pentair 476000 is the combustion blower replacement kit for the ETi 400 high efficiency pool heater. It includes the blower, a new blower adapter and gasket, PVC pressure tubing and fittings. The ETi 400 has two combustion blowers; this kit replaces one.
- Genuine Pentair kit 476000 for the ETi 400
- Blower enclosed motor (472285) and Hi-E blower adapter (475343)
- Blower adapter gasket (475360)
- Replacement PVC tubing, tee and straight fitting
- Installation guide 476110 included
Description
The Pentair 476000 is the combustion blower replacement kit for the ETi 400 high efficiency pool heater. It includes the blower, a new blower adapter and gasket, PVC pressure tubing and fittings. The ETi 400 has two combustion blowers; this kit replaces one.
- Genuine Pentair kit 476000 for the ETi 400
- Blower enclosed motor (472285) and Hi-E blower adapter (475343)
- Blower adapter gasket (475360)
- Replacement PVC tubing, tee and straight fitting
- Installation guide 476110 included
Shipping & Returns
Shipping: We offer free standard shipping on all orders within the contiguous United States (lower 48). We do not currently ship to Alaska, Hawaii, or Puerto Rico. Any other restrictions will be shown at checkout. We do not currently ship internationally. Orders ship within 1 to 2 business days, and delivery typically takes 4 to 6 business days after shipping, for a total of about 5 to 8 business days from your order date.
Tracking information is emailed once your order ships. We do not currently offer international shipping. See our full Shipping Policy for full details.
Returns: Unused items in their original packaging may be returned within 30 days of delivery. To start a return, request a Return Merchandise Authorization (RMA) by emailing support@nationalpoolsupply.com or calling +1 978-222-0628 with your order number and the reason for the return (include photos if the item is defective, damaged, or incorrect). Once your RMA is approved, ship the item with your RMA number to: DHB Enterprises LLC / National Pool Supply, 30 Log Bridge Rd, Building 300, Unit 301, Middleton, MA 01949. Change-of-mind returns: you pay return shipping, and a 15% restocking fee applies; original shipping costs are not refunded. Defective, damaged, or incorrect items reported within 30 days of delivery are returned at no cost to you with a prepaid label, and no restocking fee applies. See our full Refund and Returns Policy for full details.
Warranty
Manufacturer Warranty:
This product carries the manufacturer's warranty, where applicable. Warranty terms, coverage, and exclusions are set by the manufacturer. Warranty claims are filed directly with the manufacturer; we do not process warranty claims or offer a separate warranty of our own. If you need the manufacturer's contact details, contact us and we will share them. See our Warranty page for details.
Pentair 476000 Combustion Blower Replacement Kit for ETi 400 Heaters
- Part #
- 476000
- Brand
- Pentair
The ETi 400 has two combustion blowers, one on each heat exchanger. Each blower draws in air and gas through an air orifice and pushes the mixture into the burner. Pentair's kit replaces one blower along with the adapter, gasket and pressure tubing around it.
The air orifice and air flow switch are not in the kit. They come off the old blower and move to the new one. Pentair warns that the air orifice is sized for the burner and must not be modified or replaced with a different size.
Blower operation is checked with a differential pressure gauge on the pressure switch tubes. Pentair gives a nominal 2.0 in. W.C. for the ETi 400.
| MPN | 476000 |
|---|---|
| Heater | Pentair ETi 400 high efficiency heater |
| Blowers per heater | 2 (kit replaces one) |
| Blower pressure differential | 2.0 in. W.C. nominal |
| Gas inlet pressure | 4 in. min. / 12 in. max. W.C. |
| Manifold pressure | -0.2 in. W.C. (blower inlet tap) |
| Recommended CO2 | Natural gas 7.8-9.2%; propane 9.6-10.2% |
- Blower enclosed motor, 472285 (1)
- Blower adapter Hi-E, 475343 (1)
- Gasket, blower adapter, 475360 (1)
- PVC tubing 0.25 in. ID x 0.375 in. OD x 7.5 in., 475845 (6)
- PVC tubing 0.25 in. ID x 0.375 in. OD x 15.5 in., 475847 (1)
- 1/4 in. tee fitting, 475850 (1)
- Straight connector fitting 1/8 in. NPT x 0.25 in., 33202-0659 (1)
- Hex nut with lock washer 5/16-18, 35406-4324 (4)
- Installation guide, 476110 (1)
- Pentair requires installation by authorized service personnel qualified in pool and spa heaters.
- Turn off the heater's power, the pump and the manual gas supply valve before starting.
- Move the air orifice and air flow switch from the old blower to the new one. Install the new adapter and gasket, then the new tubing between the air flow switch, blower and gas valve.
- Leak-test the blower outlet flange and gas line with soapy water, then run the heater at least 10 minutes and check CO2 with a combustion analyzer.
- Tools listed by Pentair include a manometer to 14 in. W.C., a differential pressure gauge reading to 0.05 in. W.C. and a T20 Torx driver.
Do I need two kits?
Only if both blowers have failed. The ETi 400 has two blowers and each kit contains one.
Is the air orifice included?
No. Reuse the air orifice from the old blower. Pentair warns against modifying it or using a different size.
Can a homeowner install it?
Pentair states the kit must be installed by authorized service personnel, because the work involves gas connections and combustion testing.
Heater repairs must be done by a qualified heater service technician.