Hayward IDXLBWR1930 Combustion Blower, 240 V, for H-Series Low NOx Induced-Draft Heaters
The Hayward IDXLBWR1930 is the 240 V combustion blower for Hayward H-Series Low NOx induced-draft heaters. Hayward support identifies IDXLBWR1930 as the 240 V blower and IDXLBWR1931 as the 120 V blower, so match the voltage of the blower you are replacing.
- Hayward part IDXLBWR1930, UPC 610377625944
- 240 V combustion blower
- Item 2 in Hayward's H250IDL2/H350IDL2/H400IDL2 parts list
- 120 V version: IDXLBWR1931
- 1-year Hayward replacement part warranty
Gas and heater service must be done by a qualified heater technician.
Description
The Hayward IDXLBWR1930 is the 240 V combustion blower for Hayward H-Series Low NOx induced-draft heaters. Hayward support identifies IDXLBWR1930 as the 240 V blower and IDXLBWR1931 as the 120 V blower, so match the voltage of the blower you are replacing.
- Hayward part IDXLBWR1930, UPC 610377625944
- 240 V combustion blower
- Item 2 in Hayward's H250IDL2/H350IDL2/H400IDL2 parts list
- 120 V version: IDXLBWR1931
- 1-year Hayward replacement part warranty
Gas and heater service must be done by a qualified heater technician.
Shipping & Returns
Shipping: We offer free standard shipping on all orders within the contiguous United States (lower 48). We do not currently ship to Alaska, Hawaii, or Puerto Rico. Any other restrictions will be shown at checkout. We do not currently ship internationally. Orders ship within 1 to 2 business days, and delivery typically takes 4 to 6 business days after shipping, for a total of about 5 to 8 business days from your order date.
Tracking information is emailed once your order ships. We do not currently offer international shipping. See our full Shipping Policy for full details.
Returns: Unused items in their original packaging may be returned within 30 days of delivery. To start a return, request a Return Merchandise Authorization (RMA) by emailing support@nationalpoolsupply.com or calling +1 978-222-0628 with your order number and the reason for the return (include photos if the item is defective, damaged, or incorrect). Once your RMA is approved, ship the item with your RMA number to: DHB Enterprises LLC / National Pool Supply, 30 Log Bridge Rd, Building 300, Unit 301, Middleton, MA 01949. Change-of-mind returns: you pay return shipping, and a 15% restocking fee applies; original shipping costs are not refunded. Defective, damaged, or incorrect items reported within 30 days of delivery are returned at no cost to you with a prepaid label, and no restocking fee applies. See our full Refund and Returns Policy for full details.
Warranty
Manufacturer Warranty:
This product carries the manufacturer's warranty, where applicable. Warranty terms, coverage, and exclusions are set by the manufacturer. Warranty claims are filed directly with the manufacturer; we do not process warranty claims or offer a separate warranty of our own. If you need the manufacturer's contact details, contact us and we will share them. See our Warranty page for details.
Hayward IDXLBWR1930 Combustion Blower, 240 V, for H-Series Low NOx Induced-Draft Heaters
- Part #
- IDXLBWR1930
- Brand
- Hayward
- Voltage
- 240 V (Hayward support)
In an H-Series Low NOx induced-draft heater, the combustion blower supplies the air that mixes with the gas at the burners. Hayward's manual describes the sequence: the blower runs for 20 seconds to purge the heater, the gas valve opens and the heater lights, and the blower keeps running while the valve is open and for 30 seconds after it closes.
A blower vacuum switch proves the blower is running before the control allows ignition. A failed blower therefore stops the heater from firing.
Hayward makes this blower in two voltages. Hayward support identifies IDXLBWR1930 as 240 V and IDXLBWR1931 as 120 V. Check the label on your existing blower motor and order the matching part.
Will it fit?
Check this part against your equipment before you order.
- Hayward's installation manual 1303026201 for the H250IDL2, H350IDL2 and H400IDL2 lists IDXLBWR1930 as item 2, combustion blower.
- Hayward support identifies IDXLBWR1930 as the 240 V blower and IDXLBWR1931 as the 120 V blower. If your blower motor is 120 V, order IDXLBWR1931.
- Hayward asks that parts be ordered with the heater's model and serial number from the data plate.
| MPN | IDXLBWR1930 |
|---|---|
| UPC | 610377625944 |
| Description | Combustion blower |
| Voltage | 240 V (Hayward support) |
| Heater series | Hayward H-Series Low NOx induced draft |
| Parts list item | 2 (manual 1303026201, H250IDL2/H350IDL2/H400IDL2) |
| Shipping weight | 11.2 lb |
| Warranty | 1 year (replacement part) |
- IDXLBWR1931: combustion blower, 120 V
- IDXL2BVS1930: blower vacuum switch
- IDXL2VPS1930: vent pressure switch
One Hayward combustion blower.
- Turn off the pump, the main gas valve and the heater power.
- Remove the hot vent screws and panel, then the main top.
- Disconnect the wires and hoses attached to the blower and remove the air deflector.
- Remove the screws holding the blower to the flue collector, take the vent off the blower and replace the blower.
- Reassemble in reverse order.
What is the difference between IDXLBWR1930 and IDXLBWR1931?
Voltage. Hayward support says the 1930 is 240 V and the 1931 is 120 V.
Which one does my heater use?
Read the voltage on your current blower motor and give your dealer the heater's model and serial number from the data plate.
Will the heater run without the blower?
No. The blower vacuum switch must prove the blower is running before the control lets the heater fire.

Pool and Spa Parts & Supplies
Why Choose National Pool Supply?
We're dedicated to offering pool and spa products from leading brands. At National Pool Supply, your pool’s care is our priority, and we’re here to make your experience effortless.