Hayward UHXNEGVT12506 Negative Pressure Vertical Indoor Vent Kit, 6 in., H250FD

$276.75
Shipping calculated at checkout.

The Hayward UHXNEGVT12506 converts a Universal H-Series H250FD gas heater for indoor installation with negative-pressure (Category I) vertical venting. It replaces the heater's top flue cover and adds a 6 in. vent adapter for galvanized vent pipe that ends above the roof.

  • Hayward part UHXNEGVT12506, UPC 610377396318
  • For Universal H-Series H250FD (FDN or FDP models)
  • Category I negative pressure, vertical venting only
  • 6 in. vent adapter; single- or double-wall galvanized pipe
  • Certified to ANSI Z21.56/CSA 4.7

Vent kit installation must be done by a qualified, licensed heater technician.

In stock
  • Free shipping on all orders within the lower 48 states!
Description

The Hayward UHXNEGVT12506 converts a Universal H-Series H250FD gas heater for indoor installation with negative-pressure (Category I) vertical venting. It replaces the heater's top flue cover and adds a 6 in. vent adapter for galvanized vent pipe that ends above the roof.

  • Hayward part UHXNEGVT12506, UPC 610377396318
  • For Universal H-Series H250FD (FDN or FDP models)
  • Category I negative pressure, vertical venting only
  • 6 in. vent adapter; single- or double-wall galvanized pipe
  • Certified to ANSI Z21.56/CSA 4.7

Vent kit installation must be done by a qualified, licensed heater technician.

Shipping & Returns

Shipping: We offer free standard shipping on all orders within the contiguous United States (lower 48). We do not currently ship to Alaska, Hawaii, or Puerto Rico. Any other restrictions will be shown at checkout. We do not currently ship internationally. Orders ship within 1 to 2 business days, and delivery typically takes 4 to 6 business days after shipping, for a total of about 5 to 8 business days from your order date.

Tracking information is emailed once your order ships. We do not currently offer international shipping. See our full Shipping Policy for full details.

Returns: Unused items in their original packaging may be returned within 30 days of delivery. To start a return, request a Return Merchandise Authorization (RMA) by emailing support@nationalpoolsupply.com or calling +1 978-222-0628 with your order number and the reason for the return (include photos if the item is defective, damaged, or incorrect). Once your RMA is approved, ship the item with your RMA number to: DHB Enterprises LLC / National Pool Supply, 30 Log Bridge Rd, Building 300, Unit 301, Middleton, MA 01949. Change-of-mind returns: you pay return shipping, and a 15% restocking fee applies; original shipping costs are not refunded. Defective, damaged, or incorrect items reported within 30 days of delivery are returned at no cost to you with a prepaid label, and no restocking fee applies. See our full Refund and Returns Policy for full details.

Warranty

Manufacturer Warranty:
This product carries the manufacturer's warranty, where applicable. Warranty terms, coverage, and exclusions are set by the manufacturer. Warranty claims are filed directly with the manufacturer; we do not process warranty claims or offer a separate warranty of our own. If you need the manufacturer's contact details, contact us and we will share them. See our Warranty page for details.

U.S. Based Company
Premium Products
Trusted Pool & Spa Brands
Education & Resources
U.S. Based Company
Premium Products
Trusted Pool & Spa Brands
Education & Resources
U.S. Based Company
Premium Products
Trusted Pool & Spa Brands
Education & Resources
U.S. Based Company
Premium Products
Trusted Pool & Spa Brands
Education & Resources
U.S. Based Company
Premium Products
Trusted Pool & Spa Brands
Education & Resources
U.S. Based Company
Premium Products
Trusted Pool & Spa Brands
Education & Resources

Hayward UHXNEGVT12506 Negative Pressure Vertical Indoor Vent Kit, 6 in., H250FD

Part #
UHXNEGVT12506
Brand
Hayward

To install a Universal H-Series heater indoors, Hayward offers two vent kit families: UHXNEGVT for negative-pressure Category I vertical venting, and UHXPOSHZ for positive-pressure Category III horizontal or vertical venting. The UHXNEGVT12506 is the negative-pressure kit for the H250FD.

With this kit, the vent pipe is sized from the Category I tables in the National Fuel Gas Code and must terminate vertically above the roof. Standard galvanized single-wall or double-wall (Type B) vent pipe is used. Single-wall pipe is allowed only in conditioned spaces.

The kit replaces the factory top flue cover and top/rear panel, and the heat barrier and rain guard are removed. On earlier heaters where the vent pressure switch is on the side panel or missing, the kit's vent pressure switch, jumper wire and hose are installed too.

Will it fit?

Check this part against your equipment before you order.

  • Hayward Universal H-Series H250FD heaters (H250FDN, H250FDP).
  • For other sizes Hayward lists matching kits: UHXNEGVT11506 (H150FD), UHXNEGVT12006 (H200FD), UHXNEGVT13008 (H300FD), UHXNEGVT13508 (H350FD), UHXNEGVT14008 (H400FD) and UHXNEGVT15008 (H500FD).
  • For horizontal or positive-pressure venting on the H250FD, Hayward lists UHXPOSHZ12506 instead. Positive and negative adapters are not interchangeable.

MPNUHXNEGVT12506
UPC610377396318
BrandHayward
HeaterUniversal H-Series H250FD (model numbers ending FDN or FDP)
Vent typeNegative pressure, Category I, vertical only
Adapter size6 in.
Vent pipeSingle- or double-wall (Type B) galvanized, non-sealed
TerminationVertical, above the roof of the building
CertificationANSI Z21.56/CSA 4.7
Shipping dimensions14.4 x 20.3 x 32.8 in.
Shipping weight18 lb
Warranty1 year (replacement part)
InstructionsHayward venting kit instructions 1301666501 Rev J

Per Hayward's kit drawing: negative vent adapter, adapter gasket, vent shield, shield gaskets, screws and the kit top flue cover. The kit also contains a vent pressure switch, jumper wire and hose for earlier heaters. Vent pipe is not included.

  • Install to the National Fuel Gas Code (ANSI Z223.1/NFPA 54), the vent maker's instructions and local code.
  • Indoor clearances: 36 in. top, 18 in. front, 12 in. water connection side, 6 in. back and opposite side. Don't install in a closet or confined space.
  • Clearance to combustibles: 9 in. for single-wall vent, 6 in. for double-wall vent.
  • Never common-vent the heater with other gas appliances.
  • Above 2,000 ft, Hayward also requires high altitude conversion kit FDXLHAK1931.

Can I vent horizontally through a wall with this kit?
No. UHXNEGVT kits are vertical only. Hayward's horizontal option is the positive-pressure UHXPOSHZ kit.

Does it fit an H200FD or H400FD?
No. Each heater size has its own kit. This one is for the H250FD only.

What vent pipe do I need?
Galvanized single-wall or double-wall (Type B) vent pipe, sized from the Category I tables in the National Fuel Gas Code. Single-wall is allowed only in conditioned spaces.

Is vent pipe included?
No. The kit includes the heater-side parts only.

Free Shipping

Free standard shipping on all orders to the contiguous U.S. (lower 48). Orders ship within 1 to 2 business days. See Shipping Policy

30-Day Returns

30-day returns on unused items (RMA required; 15% restocking fee and customer-paid return shipping on change-of-mind returns). See Refund & Return Policy.

Trusted Brands

Brand-name pool products.

On-Staff Pool Pros

Call or email us for expert help when you need it.

Pool and Spa Parts & Supplies

Why Choose National Pool Supply?

We're dedicated to offering pool and spa products from leading brands. At National Pool Supply, your pool’s care is our priority, and we’re here to make your experience effortless.

Learn More