
Hayward UHXNEGVT14008 Negative Pressure Vertical Indoor Vent Kit, 8 in., H400FD
The Hayward UHXNEGVT14008 converts a Universal H-Series H400FD gas heater for indoor installation with negative-pressure (Category I) vertical venting. It replaces the heater's top flue cover and adds an 8 in. vent adapter for galvanized vent pipe that ends above the roof.
- Hayward part UHXNEGVT14008, UPC 610377396288
- For Universal H-Series H400FD (FDN or FDP models)
- Category I negative pressure, vertical venting only
- 8 in. vent adapter; single- or double-wall galvanized pipe
- Certified to ANSI Z21.56/CSA 4.7
Vent kit installation must be done by a qualified, licensed heater technician.
Description
The Hayward UHXNEGVT14008 converts a Universal H-Series H400FD gas heater for indoor installation with negative-pressure (Category I) vertical venting. It replaces the heater's top flue cover and adds an 8 in. vent adapter for galvanized vent pipe that ends above the roof.
- Hayward part UHXNEGVT14008, UPC 610377396288
- For Universal H-Series H400FD (FDN or FDP models)
- Category I negative pressure, vertical venting only
- 8 in. vent adapter; single- or double-wall galvanized pipe
- Certified to ANSI Z21.56/CSA 4.7
Vent kit installation must be done by a qualified, licensed heater technician.
Shipping & Returns
Shipping: We offer free standard shipping on all orders within the contiguous United States (lower 48). We do not currently ship to Alaska, Hawaii, or Puerto Rico. Any other restrictions will be shown at checkout. We do not currently ship internationally. Orders ship within 1 to 2 business days, and delivery typically takes 4 to 6 business days after shipping, for a total of about 5 to 8 business days from your order date.
Tracking information is emailed once your order ships. We do not currently offer international shipping. See our full Shipping Policy for full details.
Returns: Unused items in their original packaging may be returned within 30 days of delivery. To start a return, request a Return Merchandise Authorization (RMA) by emailing support@nationalpoolsupply.com or calling +1 978-222-0628 with your order number and the reason for the return (include photos if the item is defective, damaged, or incorrect). Once your RMA is approved, ship the item with your RMA number to: DHB Enterprises LLC / National Pool Supply, 30 Log Bridge Rd, Building 300, Unit 301, Middleton, MA 01949. Change-of-mind returns: you pay return shipping, and a 15% restocking fee applies; original shipping costs are not refunded. Defective, damaged, or incorrect items reported within 30 days of delivery are returned at no cost to you with a prepaid label, and no restocking fee applies. See our full Refund and Returns Policy for full details.
Warranty
Manufacturer Warranty:
This product carries the manufacturer's warranty, where applicable. Warranty terms, coverage, and exclusions are set by the manufacturer. Warranty claims are filed directly with the manufacturer; we do not process warranty claims or offer a separate warranty of our own. If you need the manufacturer's contact details, contact us and we will share them. See our Warranty page for details.
Hayward UHXNEGVT14008 Negative Pressure Vertical Indoor Vent Kit, 8 in., H400FD
- Part #
- UHXNEGVT14008
- Brand
- Hayward
An H400FD installed indoors needs a vent kit in place of its outdoor top. Hayward makes two families: UHXNEGVT for negative-pressure Category I vertical venting and UHXPOSHZ for positive-pressure Category III horizontal or vertical venting. The UHXNEGVT14008 is the negative-pressure kit for the H400FD.
The vent pipe is sized from the Category I tables in the National Fuel Gas Code and must end vertically above the roof, using single- or double-wall galvanized, non-sealed pipe. During installation the heat barrier and rain guard come out, and the kit's top flue cover, vent pipe adapter plate and filler plate go in.
One step applies only to this size: on an H400FDP (propane), Hayward's instructions say to replace the blower air inlet plate with the new plate included in the kit.
Will it fit?
Check this part against your equipment before you order.
- Hayward Universal H-Series H400FD heaters (H400FDN, H400FDP).
- Other sizes have their own kits: UHXNEGVT11506 (H150FD), UHXNEGVT12006 (H200FD), UHXNEGVT12506 (H250FD), UHXNEGVT13008 (H300FD), UHXNEGVT13508 (H350FD), UHXNEGVT15008 (H500FD).
- For positive-pressure or horizontal venting on the H400FD, Hayward lists UHXPOSHZ14008. Positive and negative adapters are not interchangeable.
| MPN | UHXNEGVT14008 |
|---|---|
| UPC | 610377396288 |
| Brand | Hayward |
| Heater | Universal H-Series H400FD (model numbers ending FDN or FDP) |
| Vent type | Negative pressure, Category I, vertical only |
| Adapter size | 8 in. |
| Vent pipe | Single- or double-wall galvanized, non-sealed |
| Termination | Vertical, above the roof of the building |
| Certification | ANSI Z21.56/CSA 4.7 |
| Shipping dimensions | 14.4 x 20.3 x 32.8 in. |
| Shipping weight | 19.59 lb |
| Warranty | 1 year (replacement part) |
| Instructions | Hayward venting kit instructions 1301666501 Rev J |
Per Hayward's instructions: negative vent adapter with screws and adapter gasket, vent shield with shield gaskets, top flue cover (top/rear panel), filler plate, and the blower air plate used on the H400FDP. Hayward also supplies a vent pressure switch and jumper wire for earlier heaters. Vent pipe is not included.
- Turn off the pump, main gas valve and heater power before starting.
- Install to the National Fuel Gas Code (ANSI Z223.1/NFPA 54), the vent maker's instructions and local code.
- Indoor clearances: 36 in. top, 18 in. front, 12 in. water connection side, 6 in. back and opposite side. Don't install in a closet or confined space.
- Never common-vent the heater with other gas appliances.
Can I vent horizontally through a wall with this kit?
No. UHXNEGVT kits are vertical only. Hayward's horizontal option is the positive-pressure UHXPOSHZ kit.
Does it fit an H350FD or H500FD?
No. Each heater size has its own kit. This one is for the H400FD.
Is anything different for a propane H400FDP?
Yes. Hayward's instructions say to swap the blower air inlet plate for the one supplied in the kit.
Is vent pipe included?
No. The kit includes the heater-side parts only.

Pool and Spa Parts & Supplies
Why Choose National Pool Supply?
We're dedicated to offering pool and spa products from leading brands. At National Pool Supply, your pool’s care is our priority, and we’re here to make your experience effortless.




